Invasive medical devices are devices that enter the body, in whole or in part, through an orifice or through any surface of the body. In aged care that usually means urinary catheters, feeding tubes and intravascular lines. Each one adds an infection risk, so each one needs a record trail that shows why it is in place, who is authorised to manage it, when it was last reviewed and when it came out.
This guide covers the definition and the governance records around it: a device register, competency and authorisation, review and removal records, and incident linkage. It contains no clinical technique. How a device is inserted or maintained is a matter for your clinical procedures and the qualified staff who follow them.
Key Takeaways
- The Australian Guidelines for the Prevention and Control of Infection in Healthcare define an invasive medical device as one that enters the body through an orifice or any body surface.
- The Guidelines name four common groups: drainage catheters such as urinary catheters, intravascular access catheters, mechanical ventilation devices and feeding devices.
- Outcome 5.2 of the strengthened Aged Care Quality Standards expects processes for using, managing and reviewing invasive devices, including urinary catheters.
- A device register links each device to its reason, review dates, authorised staff, removal and any related incident.
- The Aged Care Rules 2025 require incident details to be kept for 7 years.
What Counts as an Invasive Medical Device?
The definition comes from the Australian Guidelines for the Prevention and Control of Infection in Healthcare, published by the National Health and Medical Research Council with the Australian Commission on Safety and Quality in Health Care. Its glossary describes devices that penetrate skin, mucous membranes, organs or internal cavities, with examples such as surgical instruments, implantable devices, dental equipment and intravascular devices. That Commission's standard for health services adds dental implants, curettes, podiatry forceps and acupuncture needles as examples, which shows the definition reaches well beyond catheters.
Which of the Following Are Considered Invasive Medical Devices?
Section 3.5.2 of the Guidelines lists the devices most relevant to care settings:
- Drainage catheters: for example an indwelling urinary catheter.
- Intravascular access catheters: peripheral intravenous catheters, peripherally inserted central catheters and central venous catheters.
- Ventilation devices: devices for mechanical ventilation, such as intubation.
- Feeding devices: for example enteral feeding tubes.
The test is whether the device enters the body. Governa's glossary entry on invasive devices gives staff a one-page reference. If a team is unsure whether a particular item belongs on the register, the clinical manager decides and records the reason, so the same question is not argued again on the next shift.
Why Do Invasive Devices Sit Under Outcome 5.2?
The Aged Care Quality and Safety Commission places invasive devices inside Outcome 5.2, preventing and controlling infections in delivering clinical care services. Action 5.2.2 expects processes to minimise and manage infection that include using, managing and reviewing invasive devices, including urinary catheters. The Commission's page on Outcome 5.2 lists invasive devices as one reason older people are more vulnerable to infection.
Outcome 5.2 builds on the general infection prevention and control processes in Outcome 4.2. The device register is not a separate system. It belongs inside your infection prevention and control policy, alongside the IPC lead arrangements covered in our guide to the IPC lead role and policy requirements.
What Should an Invasive Device Register Hold?
Good practice statement 36 in the Guidelines says facilities should have processes covering insertion, use and maintenance, and removal, centred on using a device only when essential and removing it as soon as it is no longer needed. A register makes that principle checkable. As good practice, each entry holds:
- Resident and device: who has the device, what type it is, and the date it was inserted or arrived with the resident from hospital.
- Reason recorded: the documented clinical reason, entered by the clinician responsible, not by administration staff.
- Planned review: the next review date and the plan for timely removal, which the Australian Commission on Safety and Quality in Health Care's IPC workbook says should be considered before insertion.
- Review history: each review date, who reviewed it, and the decision to keep or remove.
- Removal: the date and the role of the person who removed it.
- Linked records: references to any incident, infection or hospital transfer connected to the device.
The Infection Prevention and Control Workbook also says organisations should monitor device-related infection rates. A register with consistent fields makes those rates countable.
Hospital transfers are an easy place to lose track. When a resident comes back from hospital with a new device, the receiving registered nurse adds it to the register on arrival, records the reason given in the discharge information and sets a first review date. If the reason is missing, ask the hospital for it rather than leaving the field blank.
How Do Competency and Authorisation Records Work?
The Commission's guidance on Outcome 5.2 says clinical procedures should only be done by qualified and trained workers or health professionals, within their scope of practice. The Guidelines add that staff should be adequately trained and competent for insertion, maintenance and removal. Your records need to prove both.
- Authorised procedures list: which device tasks each role may perform, approved by the clinical governance committee or director of nursing.
- Competency record: for each worker, the device tasks assessed, the date, the assessor and the next reassessment date.
- Training link: training on clean procedures and aseptic technique recorded against the same worker profile.
- Agency and new staff: a check, before the first shift, that the person is authorised for any device task on the roster.
As good practice, the roster coordinator checks the authorised procedures list when a resident with a device is allocated. A gap is escalated to the registered nurse in charge before the shift starts, not after.
How Should Device Incidents Link to the Register?
Outcome 2.5 expects an incident management system that records, investigates, responds to and manages incidents and near misses. A device-related infection, a dislodged catheter or a missed review date are all candidates for that system. The incident record should cite the register entry, and the register should show the incident reference, so either record leads to the other.
A clear escalation path helps. The registered nurse in charge records the event and notifies the clinical manager. The clinical manager checks the register, the review history and the competency of the staff involved. The IPC lead reviews device-related infection trends, and the clinical governance committee reports patterns to the governing body. Incident details must be kept for 7 years under the Rules.
Antibiotic use that follows a device-related infection also feeds your stewardship data. Our article on antimicrobial stewardship for aged care providers covers that side.
Make Every Device Traceable From Day One
Invasive medical devices are a known infection risk, and Outcome 5.2 expects providers to show how each one is used, managed and reviewed. A register that records the reason, review dates, authorised staff, removal and linked incidents turns that expectation into evidence. Start by listing every resident with a device today and checking that each entry has a next review date and a named reviewer.
Related Resources
- Infection prevention and control policy template
- Incident management and reporting policy template
- Workforce training and competency policy template
- The IPC lead role and policy requirements
- What providers need for antimicrobial stewardship
- Mapping your policies to the Quality Standards
- The Commission's guidance on Outcome 5.2
Common Questions About Invasive Medical Devices in Aged Care
1. Which of the following are considered invasive medical devices?
The Guidelines list catheters for drainage such as urinary catheters, catheters for intravascular access, devices for mechanical ventilation and devices for feeding such as enteral feeding tubes. The broader definition covers any device that enters the body through an orifice or a body surface.
2. Is a urinary catheter an invasive device?
Yes. The Guidelines name urinary catheters as an example of drainage catheters, and Action 5.2.2 of the strengthened Quality Standards mentions urinary catheters by name.
3. What records should an aged care provider keep for invasive devices?
As good practice, keep a register showing the device, the documented reason, review dates and decisions, removal, and links to any incident. Pair it with competency and authorisation records for the staff who manage each device.
4. Who can manage invasive devices in aged care?
The Commission says clinical procedures should only be done by qualified and trained workers or health professionals within their scope of practice. Your authorised procedures list and competency records should show who that is for each task.
5. Where do invasive devices fit in the strengthened Quality Standards?
They sit in Outcome 5.2, preventing and controlling infections in delivering clinical care services. Action 5.2.2 covers using, managing and reviewing invasive devices, and Outcome 5.2 builds on the general infection prevention and control processes in Outcome 4.2.